Extensometer Force Transducer

Extensometers govern the accuracy of the Roll Force Measurement System. Although similar in operating principal to a load cell, an extensometer is calibrated in strain (or stretch) instead of load. Actually, where maximum roll force may vary considerably from mill to mill, post strain remains within a range of 33 to 130 microinches per inch. extensometers are designed for optimum performance over this range. Installing extensometers on both the work and drive sides of the mill enables the user to achieve a balanced force at all times. With extensometers installed, the mill posts become an active part of the measuring system. The entire mill housing with the attached extensometer can be considered a “load cell”. For additional system information, please refer to the G4 and RFS4 datasheets.

Placeholder
1393ipd_06936b134997d4f.jpg

Documentation

Extensometer Force Transducer | Data Sheet

Data Sheet

Specifications

Overview

Features
Simple bolt-on installation
No mill stand alterations required
Accuracy: ± 0.85% of full scale output
Repeatability: 0.5% of full scale output
No damage results from accidental mill overload

Application: Strip & Web Tension
Industry: Metal
Material: Stainless Steel
Product Type: Force Transducers & Tension Measurement Modules

Data
Benefits

Get in Touch

Need Help With A Product?

We work closely with a diverse network of manufacturers to bring you a wide range of instrumentation equipment options, ensuring that you find the perfect fit for your requirements.